|
Kubus - Update |
Kubus-Update |
|||||
Update-description: |
Various updates after completion of Kubus 7.6 |
||||
Kubus-Version: |
7.6 |
Update: |
A |
Date of creation: |
2017-07-19 |
Update-components |
Version |
(s.u.: nominal-view installed updates |
7.6.0.1 |
TXUtilities.dll,
gtcConverterV31.dll |
|
Behobene Tickets |
EARS00002080544 - Oncost distribution in the bid: Algorithmics SDF EARS00002080570 - Oncost distribution in the bid: Algorithmics variant-item EARS00002080574 - Oncost distribution in the bid: Fauld GUI B/V EARS00002080548 - Oncost distribution in the bid: Algorithmics Input the BP total EARS00002103954 - PSL:
Open Subprojects - Cursor scrolls down EARS00002064058 - Open bid, then delete I - Fauld in DC EARS00002114443 - WI – Longtext with
image EARS00002113522 - Last item while open table – structur EARS00002104040 - GAEB-import of a file with GAEB2000 form EARS00002001245 - Longtext-view – text width EARS00002116592 - Report bid - Oncost distribution rows |
EARS-ID: |
EARS00002080544 - Oncost distribution in the bid: Algorithmics SDF |
Problem: |
In the
course of the Oncost distribution in the bid noted that the SDF is not included in
the distribution algorithm. This only occurs when fixed items and the items
whose oncost% value is changed do not have the same SDF. |
Solution: |
The problem was
solved. The SDF will be considered now. |
EARS-ID: |
EARS00002080570 – Oncost distribution in the
bid: Algorithmics variant-item |
Problem: |
If in a bid the items
(including basic and variant items) and oncost distributions was fixed and
the function "Apply UPs of variants" was activated, then a mark up
was changed in a contribution cost type group then the variant items were not
handled correctly during distribution. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002080574 – Oncost
distribution in the bid: Fauld GUI B/V |
Problem: |
All items that follow within a group of a variant items are not displayed
in the function: "Change oncost allocation". Fault is also
reproducible in KUBUS 7.5. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002080548 – Oncost distribution in the bid: Algorithmics Input the BP total |
Problem: |
The entry of bid price
does not provide the expected result (TF59-5). Siehe auch
EARS00002054769. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002103954 - PSL: Open Subprojects - Cursor scrolls down |
Problem: |
If the option "Work with sub-projects"
was activated in option manager, the cursor jumped to the last item in the
project structure list if you wanted to open a sub-project (by
double-clicking). |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002064058 – Open bid, then delete I -
Fauld in DC |
Problem: |
The view:
"table" was not updated after saving the direct cost - WI. After closing and
saving the bid, Kubus was crashed. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002114443 - WI
– Longtext with image |
Problem: |
An WI was imported via the GAEB DA XML
interface. A long text with graphics was not displayed in the langtext view. |
Solution: |
For the visualization of the long texts
(XHTML) they have to be converted to RTF. The problem was a large graphic,
which could not be converted for storage reasons because the conversion is
done with the flag WMeteFile8 by default and the result is very large. Since
the text control used in the longtext does not require this setting, the
editing is now carried out without this flag, which means that significantly
less space is required and the graphics in the long text are displayed. |
EARS-ID: |
EARS00002113522 - Last item while open table – structur |
Problem: |
When opening an WI in the view: "structure" or even when saving
a current view, the cursor jumps to the last item. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002104040 – GAEB-import of a file with
GAEB2000 form |
Problem: |
If a
file was created with the GAEB2000 export and then imported again with GAEB
DA XML, the short and long texts were not imported correctly. |
Solution: |
The problem was solved |
EARS-ID: |
EARS00002001245 – Longtext-view – text width |
Problem: |
In option
management (RTF text view format), the max. text width in the langtext view. The text width was sometimes not set correctly. |
Solution: |
The problem was solved. |
EARS-ID: |
EARS00002116592 - Report bid - Oncost
distribution rows |
Problem: |
The
elements of the transfer lines were not consistently positioned. |
Solution: |
The report was customized |
To be display „Installed Updates“ |
|||||||||||||||||||||||||||||||||||||||||||||||
Kubus-Version: |
7.6 |
|
|||||||||||||||||||||||||||||||||||||||||||||
Update: |
A |
||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
Update-components |
Product version |
File version |
remark |
||||||||||||||||||||||||||||||||||||||||||||
The ToBe-Display also lists client-specific
files, but without product- and file version. These files may not appear at
every customer, and if, may vary in its product and file version. |